Model 6250

The Model 6250 is designed to test most light jets. It is used to perform leak checks and RVSM accuracy checks on the Pitot-Static systems – including altimeters, airspeed indicators and VSI’s – and can be done at low airspeeds. The Model 6250 includes a Remote unit with large keypad and display, a removable 8-hour battery (optional), wide operating temperature (optional), and “profiles” to accelerate testing. The unit can be controlled by an iPad or other tablets.

Request a quote?

STATIC PORT

Pressure Function

Range: 1.0 to 32 inHg

Resolution: 0.001 inHg

Accuracy: ±0.003 inHg

Units: inHg mbar, psi, mmHg, kpa

Pressure Rate

Range: 0 to 30 inHg/min

Resolution: 0.001 inHg/min

Accuracy: ±1% of rate

Units: pressure-units/min

Altitude Function

Range: -2000 ft to 50,000 ft

Resolution: 1 ft

Accuracy:

  • ± 3 ft @ 0 ft
  • ± 4 ft @ 10,000 ft
  • ± 6 ft @ 20,000 ft
  • ± 9 ft @ 35,000 ft
  • ± 18 ft @ 50,000 ft

Units: feet, meters

Climb Function

Range: 0 ft/min to ±10,000 ft/min

Resolution: 1 ft/min

Accuracy: ±1% of rate of climb

Units: ft/min, meters/sec

SYSTEM

Power Requirement

90-260 VAC, 47-440 Hz, 100W (200W with heaters)

Removable Battery (optional): 6 to 8 hours of operation

External Interfaces

Wi-Fi, RS232 Serial, Encoder (optional)

Dimensions & weights

Main unit: 22” x 14” x 9” / 30 lbs

Remote unit: 6” x 6” x 1” / 1.8 lbs

Environmental Specs

Operating temp: 0°C to 50°C, –40°C to 50°C (optional)

Storage temp: –40°C to 75°C

Humidity: 5 to 100%

PITOT PORT

Pressure Function

Range: 0 to 15 inHg (differential)

Resolution: 0.001 inHg

Accuracy: ±0.003 inHg

Pt Units: inHg, mbar, psi, mmHg, kpa, EPR

Qc Units: inHg, mbar, psi, mmHg, kpa

Pressure Rate

Range: 0 to 30 inHg/min

Resolution: 0.001 inHg/min

Accuracy: ±1% of rate

Units: pressure-units/min (EPR in inHg/min)

Airspeed Function

Range: 0 to 500 knots

Resolution: 0.1 knots

Accuracy:

  • ± 1.0 knots @ 20 knots
  • ± 0.3 knots @ 50 knots
  • ± 0.2 knots @ 100 knots
  • ± 0.1 knots @ 200 knots
  • ± 0.04 knots @ 500 knots

Units: knots, Mach, km/hr, mph

Rate of change: 0 to 500 knots/min

Airspeed Rate

Range: 0 to 500 knots/min

Resolution: 0.1 knots/min (0.01 km/hr/sec)

Accuracy: ±2% of rate

Units: knots/min, km/hr/sec, mph/min

Mach Function

Range: 0.0 to 1.0 Mach

Resolution: 0.001 Mach

Accuracy: ±0.001 above 0.2 Mach

Attention!